What should be paid attention to in the use of glass dropper

Apr 17, 2021

Glass dropper is used to accurately transfer a certain volume of solution. Pipette is a kind of measuring instrument, which is only used to measure the volume of the solution it releases. It is a slender glass tube with a large part in the middle. The lower end is a sharp mouth shape, and a marking line is engraved on the neck of the upper end tube, which is the mark of the accurate volume. According to the volume and requirements of the solution to be transferred, a pipette of appropriate specification is selected. Pipette is generally used to accurately transfer the solution in titration analysis. Pipette is generally used when the reaction needs to control the amount of test solution.


A pipette is an instrument for accurately transferring a certain volume of solution. When using, hold the pipette with the thumb and middle finger of the right hand, insert the pipette into the solution container, and make the lower end of the pipette extend into the lower part of the solution. Hold a ball with the left hand to remove air and align the tip of the ball with the orifice of the pipette. Because of the negative pressure in the ball, when suction, the left hand relaxes and the solution rises along the pipette. When the liquid level slightly exceeds the scale, the right index finger immediately presses the upper orifice of the pipette and lifts the pipette out of the container. Loosen the index finger slightly, rotate the tube slowly with the thumb and middle finger to make the solution flow out drop by drop, and make the line of sight and the scale mark of the pipette at the same horizontal position. When the liquid level is tangent to the scale line, press the index finger tightly immediately. At the same time, insert the pipette into the triangular flask. Press the lower end of the vertical pipette and the upper inner wall of the slightly inclined triangular flask. At this time, release the index finger and the solution flows out quickly,. After the solution flows out and stops for about 15 seconds, the pipetting operation is completed. The solution left at the tip of the pipette does not need to be blown out. During calibration, the remaining liquid at the tip of the pipette is not included in the measuring volume of the pipette. If the "blow" character is used in the side note of the scale value, the remaining liquid at the pipe tip will be included in the volume of the container during the calibration, so it must be blown out during the operation.


Send Inquiry